Dual Tuned Quadrature Head Coil for 7 T

Dual Tuned Quadrature Head Coil for 7 T

Description

  • dual tuned coil for human head studies
  • transmit / receive quadrature polarization for both nuclei
  • available for  23Na/1H, 31P/1H, 13C/1H and 19F/1H
    (other nuclei on demand)
  • open design
  • sliding mounting mechanism for patient access
  • B0‑field strength 7 T
  • approx. housing dimensions of volume resonator: ID 26.5 cm, OD 35 cm
  • approx. weight: 7 kg
  • individually adaptable to different MR systems
  • no medical device

For a quotation on this coil please contact us.

Important note: For a Siemens Terra MR system the 23Na/1H, 31P/1H, 13C/1H and 19F/1H versions of this product are exclusively available through SIEMENS Healthcare.

Caution! Investigational device limited by Federal (or United States) Law to investigational use only.


Datasheet

Download information about Dual Tuned Quadrature Head Coil for 7 T as PDF .

Publications

Korzowski, P. Bachert: High-resolution 31P echo-planar spectroscopic imaging in vivo at 7T.
Magnetic Resonance in Medicine, Volume 79, Issue 3, 1251–1259 (2018)
with RAPID Biomedical 31P/1H dual tuned head coils # V-XQ-HQ-070-01500

K. Rink, et. al.: Nuclear-Overhauser-enhanced MR imaging of 31P-containing metabolites: Multipoint-Dixon vs. frequency-selective excitation.
Magnetic Resonance Imaging (2015). http://dx.doi.org/10.1016/j.mri.2015.07.017
with RAPID Biomedical 31P/1H dual tuned head coils # V-XQ-HQ-070-01500 (@ 7 T ) and V-XQ-HQ-030-00633 (@ 3 T)

K. Rink, et. al.: Iterative reconstruction of radially–sampled 31P bSSFP data using prior information from 1H MRI.
Magnetic Resonance Imaging, DOI: 10.1016/j.mri.2016.11.013 (2016)
with RAPID Biomedical 31P/1H dual tuned head coil # V-XQ-HQ-070-01500

F. Resmer et. al.: A 30 Channel Rx Array for 23Na Imaging of the Head at 7 Tesla.
UHF Meeting Berlin (2016)
with RAPID Biomedical 23Na/1H head coils # V-XQS-HQ-070-01657 and
P-X30LE-070-01658

J. Lommen et.al.: Comparison of a 30-channel head array with a birdcage for 23Na MRI at 7 Tesla.
ISMRM 2016 Singapore, Magna Cum Laude Award, Abstract ID 1663 (2016)
with RAPID Biomedical 23Na/1H head array # P-X30LE-070-01658

A.M. Nagel et.al.: The Potential of Relaxation-Weighted Sodium Magnetic Resonance Imaging as Demonstrated on Brain Tumors.
Investigative Radiology • Volume 46/ Number 9, 539-547 (September 2011)
with RAPID Biomedical 23Na/1H head array # P-X30LE-070-01658

 

RAPID Biomedical GmbH
Kettelerstrasse 3-11
97222 Rimpar
Germany

Phone: + 49 (0) 9365 / 88 26 – 0
Fax: + 49 (0) 9365 / 88 26 – 99

info@rapidbiomed.de
www.rapidbiomed.de

For US, Canada and South America please contact our sister company RAPID MR International.
Find information about our strategic partner Fastron Group.

Source: https://www.rapidbiomed.de/product/dual-tuned-quadrature-head-coil-for-7-t/