Siemens Terra 7 T Dual Tuned Head Coil

Siemens Terra 7 T Dual Tuned Head Coil

Description

  • dual tuned head volume resonator
  • available for 31P/1H, 23Na/1H, 13C/1H and 19F/1H
  • transmit/receive quadrature polarization for both nuclei
  • high SNR performance
  • supports proton decoupled experiments
  • sliding mounting mechanism for easy patient access
  • open design
  • B0 field strength: 7 T
  • approximate dimensions
    inner diameter: 26.5 cm
    outer diameter: 35 cm
  • other geometry upon request

No medical device, limited to investigational use.
Caution: Investigational Device. Limited by Federal (or United States) law to investigational use.

Important note! This product is exclusively available through SIEMENS Healthcare.

Please contact us for availability on other MR systems.


Publications

Korzowski, P. Bachert: High-resolution 31P echo-planar spectroscopic imaging in vivo at 7T.
Magnetic Resonance in Medicine, Volume 79, Issue 3, 1251–1259 (2018)
with RAPID Biomedical 31P/1H dual tuned head coils # V-XQ-HQ-070-01500

K. Rink, et. al.: Nuclear-Overhauser-enhanced MR imaging of 31P-containing metabolites: Multipoint-Dixon vs. frequency-selective excitation.
Magnetic Resonance Imaging (2015). http://dx.doi.org/10.1016/j.mri.2015.07.017
with RAPID Biomedical 31P/1H dual tuned head coils # V-XQ-HQ-070-01500 (@ 7 T ) and V-XQ-HQ-030-00633 (@ 3 T)

K. Rink, et. al.: Iterative reconstruction of radially–sampled 31P bSSFP data using prior information from 1H MRI.
Magnetic Resonance Imaging, DOI: 10.1016/j.mri.2016.11.013 (2016)
with RAPID Biomedical 31P/1H dual tuned head coil # V-XQ-HQ-070-01500

F. Resmer et. al.: A 30 Channel Rx Array for 23Na Imaging of the Head at 7 Tesla.
UHF Meeting Berlin (2016)
with RAPID Biomedical 23Na/1H head coils # V-XQS-HQ-070-01657 and
P-X30LE-070-01658

J. Lommen et.al.: Comparison of a 30-channel head array with a birdcage for 23Na MRI at 7 Tesla.
ISMRM 2016 Singapore, Magna Cum Laude Award, Abstract ID 1663 (2016)
with RAPID Biomedical 23Na/1H head array # P-X30LE-070-01658

A.M. Nagel et.al.: The Potential of Relaxation-Weighted Sodium Magnetic Resonance Imaging as Demonstrated on Brain Tumors.
Investigative Radiology • Volume 46/ Number 9, 539-547 (September 2011)
with RAPID Biomedical 23Na/1H head array # P-X30LE-070-01658

 

RAPID Biomedical GmbH
Technology Park Würzburg-Rimpar
Kettelerstrasse 3-11
97222 Rimpar
Germany

Phone: + 49 (0) 9365 / 88 26 – 0
Fax: + 49 (0) 9365 / 88 26 – 99

info@rapidbiomed.de
www.rapidbiomed.de

For US, Canada and South America please contact our sister company RAPI MR International.
Find information about our strategic partner Fastron Group.

Source: https://www.rapidbiomed.de/product/7-t-dual-tuned-head-coil-3/